Flame Sensing and Rectification

How a furnace proves flame with a single rod, and how to measure and interpret the microamp signal.

Concept
Technician
#furnace#heating#ignition#diagnostics

Safety

Never bypass or simulate a flame proving signal. Gas flowing without proven combustion is an explosion hazard.

What it is

A flame sensor is a single metal rod placed in the burner flame. The control board applies alternating current to the rod and the flame, being conductive and asymmetric, allows current mostly in one direction. The resulting small direct current tells the board flame is present.

Flame signal is measured in microamps, commonly 1 to 6 on residential equipment

Always compare to the minimum value the manufacturer specifies for that board.

Why it matters

Flame sensing is the safety that prevents raw gas from flowing without combustion. It is also one of the most common causes of intermittent no heat calls, because a thin oxide layer on the rod slowly reduces the signal until the board drops out after a few seconds of burner operation.

How to measure it

  1. 1Turn off power and gas, then place the meter in series with the sensor wire using the microamp range.
  2. 2Restore power and gas and start a heat call.
  3. 3Read the signal once the burners are fully lit and stable.
  4. 4Compare to the manufacturer minimum. A signal near the minimum will fail as the rod ages.
  5. 5If low, clean the rod gently with a non abrasive pad, never sandpaper, and recheck.
  6. 6If cleaning does not restore the signal, check the ground path, burner condition, gas pressure and flame quality.

Signal drops steadily during the run

Often a marginal ground or a sensor positioned at the edge of the flame

Signal is strong but the board still drops out

Suspect the board or the sensor wire insulation grounding out

Yellow or lifting flame

A combustion problem, not a sensor problem. Check gas pressure, burners and combustion air

Signal restored by cleaning but fails again within months

Look for combustion byproducts, poor burner condition or an air supply contamination issue

Safety

Never bypass flame proving

Jumping or simulating a flame signal allows gas to flow without combustion. This is never an acceptable test or repair.

Tools involved

  • Meter with a microamp direct current range
  • Alligator jumper leads
  • Non abrasive cleaning pad
  • Combustion analyzer to confirm flame quality

Symptoms

Practice & Mastery

  • Questions2
  • Quiz1
  • Flame Sensing and Rectification Troubleshooting Scenarios1

Practice is part of HVAC Pro — $5/month or $50/year.

AI Tutor

Ask AI about Flame Sensing and Rectification

The AI Tutor knows the topic you are reading and teaches from the Welcome to HVAC knowledge base. Included with HVAC Pro — $5/month or $50/year.

Next topicPressure Switch

Educational reference only. Verify procedures against manufacturer instructions and local code. Last updated 9/21/2026.

Need a human expert? Expert Help is coming soon.