Carbon Monoxide Safety

Where carbon monoxide comes from, how it is measured, and what to do when readings are elevated.

Concept
Apprentice
#safety#combustion#carbon monoxide

Safety

Carbon monoxide can be fatal. Evacuate and ventilate on elevated ambient readings, shut down the suspect appliance, and never bypass a safety control or disable an alarm.

What it is

Carbon monoxide is a product of incomplete combustion. It is colourless, odourless and tasteless, and it binds to haemoglobin far more readily than oxygen does, which is what makes low concentrations dangerous over time and higher concentrations dangerous quickly.

Sources and symptoms

  • Cracked or corroded heat exchangers.
  • Blocked, disconnected or undersized venting.
  • Insufficient combustion air or a depressurized mechanical room.
  • Dirty or misaligned burners and incorrect gas pressure.
  • Unvented appliances, vehicles running in attached garages and portable generators.

Early exposure symptoms resemble influenza without a fever: headache, nausea, dizziness and fatigue that improve when occupants leave the building. Multiple occupants or pets affected at once is a strong indicator.

Measuring it

  1. 1Turn on a personal carbon monoxide monitor before entering the building.
  2. 2Take an ambient reading in the living space before starting any appliance.
  3. 3Record ambient readings in the mechanical room and near each appliance.
  4. 4Run the appliance and measure carbon monoxide in the flue gas with an analyser.
  5. 5Repeat with the building in a worst case depressurization condition.
  6. 6Document every reading with the conditions under which it was taken.

If ambient readings are elevated

Get occupants out and ventilate the building. Shut down the suspect appliance and do not return it to service. Follow the response levels and notification requirements that apply where you work, and advise occupants to seek medical attention if anyone has symptoms.

What not to do

No shortcuts

Do not silence or remove an alarm to stop a nuisance call, do not bypass a safety control that is shutting an appliance down, and do not leave a suspect appliance operating while awaiting parts. Alarms are a last line of defence, not a diagnostic tool, and a working alarm should be present on every level of a home with fuel fired equipment or an attached garage.

Local requirements

Alarm placement requirements, acceptable carbon monoxide levels, technician response procedures and notification obligations vary by jurisdiction, adopted code edition and the regulations in force.

Local Code Notice

Alarm requirements, action levels and response obligations vary by jurisdiction, adopted code edition and the regulations in force.

Practice & Mastery

  • Questions1
  • Carbon Monoxide Safety Troubleshooting Scenarios2

Practice is part of HVAC Pro — $5/month or $50/year.

AI Tutor

Ask AI about Carbon Monoxide Safety

The AI Tutor knows the topic you are reading and teaches from the Welcome to HVAC knowledge base. Included with HVAC Pro — $5/month or $50/year.

Next topicGas Furnace: No Heat

Educational reference only. Verify procedures against manufacturer instructions and local code. Last updated 9/21/2026.

Need a human expert? Expert Help is coming soon.