Heat Pump vs Electric Resistance Heating Cost

Resistance heat has a COP of 1. A heat pump divides the same heat demand by its average COP.

HVAC Pro calculator — inputs, formula and example are open to everyone.

kWh
$/kWh

Result

Results for this calculator are part of HVAC Pro

You can see the inputs, formula and worked example. Unlock results for every Pro calculator.

Unlock with HVAC Pro

Already a member? Sign in

Formula

  • Heat pump kWh = heat needed ÷ COP
  • Cost = kWh × rate

Example calculation

15,000 kWh of heat at COP 2.8 and $0.13/kWh → $696 vs $1,950 with baseboards.

Practical HVAC use

Explain operating savings to homeowners using a realistic seasonal COP.

Common mistakes

  • Using the rated COP at 47 °F as the seasonal average in a cold climate.

Related calculators