Heat Pump vs Electric Resistance Heating Cost
Resistance heat has a COP of 1. A heat pump divides the same heat demand by its average COP.
HVAC Pro calculator — inputs, formula and example are open to everyone.
Result
Results for this calculator are part of HVAC Pro
You can see the inputs, formula and worked example. Unlock results for every Pro calculator.
Unlock with HVAC ProAlready a member? Sign in
Formula
- Heat pump kWh = heat needed ÷ COP
- Cost = kWh × rate
Example calculation
15,000 kWh of heat at COP 2.8 and $0.13/kWh → $696 vs $1,950 with baseboards.
Practical HVAC use
Explain operating savings to homeowners using a realistic seasonal COP.
Common mistakes
- Using the rated COP at 47 °F as the seasonal average in a cold climate.