Sensible and Latent Heat

The difference between heat you can measure with a thermometer and heat that removes moisture from the air.

Concept
Apprentice
#fundamentals#humidity#capacity#airflow

What it is

Sensible heat

Heat that changes the temperature of a substance. A thermometer senses it, which is where the name comes from.

Latent heat

Heat that changes the state of a substance without changing its temperature, such as water vapor condensing on a cold coil.

Total capacity is the sum of the two. A cooling coil removes sensible heat by lowering air temperature and latent heat by condensing moisture out of the air.

Why it matters

A system can hit the thermostat setpoint and still leave a house clammy if it is not removing enough latent heat. Oversized equipment short cycles, satisfies temperature quickly and never runs long enough to dehumidify.

Sensible heat ratio = sensible capacity / total capacity

A typical residential cooling coil runs a sensible heat ratio around 0.7 to 0.8 in a mixed climate.

How it works

Latent removal only begins when the coil surface is below the dew point of the air passing over it. Higher airflow raises coil temperature and shifts capacity toward sensible. Lower airflow drops coil temperature and shifts capacity toward latent, until the coil gets cold enough to freeze.

ChangeSensible capacityLatent capacity
Increase airflowUpDown
Decrease airflowDownUp until icing
Higher indoor humiditySlightly downUp
Oversized equipment with short runtimesMet quicklyPoor

How to diagnose it

Measure indoor relative humidity during a long cooling run

Above roughly 55 percent while cooling suggests poor latent removal

Measure wet bulb and dry bulb entering and leaving the coil

The enthalpy difference shows total capacity, not just sensible

Verify airflow per ton against the manufacturer target

Excess airflow is a common cause of humidity complaints

Check runtime per cycle

Very short cycles rarely dehumidify well

Where it is used

Equipment selection, blower speed setup, humidity complaints and dehumidifier sizing all depend on separating sensible from latent load.

Practice & Mastery

  • Questions2
  • Quiz1
  • Sensible and Latent Heat Troubleshooting Scenarios2

Practice is part of HVAC Pro — $5/month or $50/year.

AI Tutor

Ask AI about Sensible and Latent Heat

The AI Tutor knows the topic you are reading and teaches from the Welcome to HVAC knowledge base. Included with HVAC Pro — $5/month or $50/year.

Next topicStates of Matter and Phase Change

Educational reference only. Verify procedures against manufacturer instructions and local code. Last updated 10/23/2026.

Need a human expert? Expert Help is coming soon.